Manufacturer Part Number: 3150
SAF3150 120v Hydrostat Universal Temperature Limit and Low Water Cut Off for Oil Fired Boilers 48-3150
Part Description:
- Oil Fired Boiler Low Water Cut-Off
- Item Low Water Cut-Off
- Type 2-Function
- Overall Dimensions 4.6 Inch Width x 3.7 Inch Depth x 6.3 Inch Height
- Input Supply Rating 120 Volt AC at 60 Hertz
- Temperature Rating 110 to 200 Deg F (Low Limit), 100 to 220 Deg F (High Limit), 10 to 30 Deg F (Differential)
- Media Handled Water
- Inclusions/Features Universal Temperature Limit, Simple Dial Type Temp and Differential Setting, Dynamic Temperature Display, LED Status Light, Test/Settings Button
- Application Residential
- Applicable Standard UL
- Burner Contact Rating 7.4 Amp (Full Load) and 44.4 Amp (Locked Rotor) at 120 Volt AC
- Switching Capacity 5.8 Amp (Full Load) and 34.8 Amp (Locked Rotor) at 120 Volt AC
Features / Benefits
- Replaces Cold Start and Triple-Action Aquastats
- Install Hydrostat on Existing Immersion Well for Full Temperature Functionality Install Hydrostat on an Electro-Well to Add Low Water Cut-Off Protection
- Simple Dial-Type Temperature and Differential Settings
- Easy to Wire – Uses the Same Terminal Designations as Common Aquastat Models
- Four On-Board Diagnostic Indicating Lights
- Saves Time, Materials and Wiring